Works throughout the circulation system
The control panel energizes the replaceable probe, and moving water carries the generated copper ions through the water feature to help suppress string algae.
The IonGen System G2 uses a microprocessor-controlled copper probe to help control filamentous string algae throughout ponds, Pondless® Waterfalls, fountains and other recirculating decorative water features. It reduces reliance on repeated liquid algae treatments while giving you adjustable output and test kits for responsible water-quality monitoring.
This is a complete electronic algae-control system—not a one-time treatment. Its value comes from adjustable output, flexible installation and ongoing monitoring that lets you respond to changing conditions.
The control panel energizes the replaceable probe, and moving water carries the generated copper ions through the water feature to help suppress string algae.
For the strongest flow, install the included chamber after the pump. The probe may also be fully submerged in a skimmer, filter or Pondless Waterfall Vault using the included holder.
Aquascape states that typical electrical operating cost is less than $1 per month. The display also reads “00” when the probe is exhausted or the system detects an operating fault.
Use the official instructions for the complete procedure. These stages highlight the decisions to make before you cut plumbing or energize the probe.
Remove as much string algae and debris as practical before installation. Heavy existing growth slows visible results.
Confirm that the power cord reaches a grounded GFCI outlet and the probe lead reaches the planned probe location. Mount the weather-resistant controller above ground and protect it from severe exposure.
For best performance, plumb the flow chamber after the pump in a line that can drain by gravity. Alternatively, secure the probe with its holder in a skimmer, filter or Pondless Waterfall Vault. Keep the probe fully submerged with adequate flow.
Use the included kits to confirm total alkalinity is 100–250 ppm and to establish a copper baseline. Fish-containing features require special care: never allow copper to reach or exceed 0.25 ppm.
For a new or clean feature, begin at level 1 or 2. Raise output only when algae conditions require it, retest copper regularly and lower the setting again when conditions improve.
Test copper periodically and keep it below 0.25 ppm. Maintain total alkalinity between 100 and 250 ppm; evaporation and water changes can shift these readings during the season.
Check for wear, debris and scale. Brush or scrape scale from the bars as needed. Repeated buildup usually signals inadequate flow. Probe life varies with output setting, feature volume and water chemistry.
Shut the IonGen system down in cold climates, drain water from plumbing and the flow chamber, and inspect the probe before spring startup. Freeze damage from plumbing that was not drained can void warranty coverage.
Review the manufacturer documents before installation and keep them available for operation, maintenance, troubleshooting and winter care.
A concise product introduction from AquascapePonds, the official manufacturer channel.
AquascapePonds explains operating practices that help the IonGen G2 perform as intended.
Blue Thumb’s Sales and Technical Team can help you review feature volume, plumbing method, probe placement and the maintenance this system requires before you order.
It is designed primarily for filamentous string algae. Aquascape notes that some algae types are less affected by copper ions, so results can vary by algae type and water conditions.
Yes, when installed, tested and operated according to the manufacturer’s instructions. Keep copper below 0.25 ppm and total alkalinity between 100 and 250 ppm. Do not operate the system with fish when alkalinity is below 100 ppm.
One IonGen G2 is rated for water features up to 25,000 gallons. Larger volume, heavy existing algae and unfavorable water chemistry can increase the time required for noticeable results.
No. It is an add-on electronic algae-control system. Your water feature still needs an operating pump, circulation and appropriate mechanical and biological filtration for its design.
Not always. Plumbing the included flow chamber after the pump is the most effective method, but the probe can also be fully submerged in a skimmer, filter or Pondless Waterfall Vault using the included holder, provided it receives adequate water flow.
Results are not instant. After heavy algae and debris are removed, visible improvement may take several days to a few weeks. Water chemistry, feature volume, existing algae and flow across the probe all affect performance.
The current manual says the replaceable probe typically lasts one or more seasons, depending on use, water volume and chemistry. High output and high conductivity can shorten probe life. Inspect the bars periodically and replace the probe when significantly worn or exhausted.
Aquascape recommends shutting the system down in climates with cold temperatures. Drain the plumbing and flow chamber before freezing weather, then clean and inspect the probe before spring startup.
The display reads “00” when the probe is completely exhausted or there is an operating fault. Inspect the probe and confirm that all quick-connect cables are fully connected and undamaged before replacing components.